24 April, 2024

Ultima oil-free compressor offers major energy savings and smaller form factor

16 June, 2017

Gardner Denver has launched Ultima, a new, water-cooled oil-free compressor from its CompAir brand, offering up to 12% improved energy efficiency compared to a conventional two-stage machine with a 37% smaller footprint. Launched as part of the company’s CompAir PureAir range, Ultima is available in models from 75 kW to 160 kW and is designed for best-in-class performance, for applications that demand the highest levels of air quality and purity.


Unique drive optimisation – no gear box required

Unlike standard oil-free compressors, which have a single motor and mechanical gearbox design to drive the low- and high-pressure air ends, Ultima uses the U-Drive concept – two, high-efficiency, permanent magnetic motors which replace the gearbox and single motor.

These variable-speed motors, powered by an inverter, can achieve speeds of up to 22,000 rpm and deliver efficiencies greater than IE4.

While conventional variable-speed machines are already well proven in numerous applications and deliver high energy efficiency, the two stages of compression are linked mechanically, meaning they need to speed up and slow down at the same time.

Ultima, however, is different. By removing the gearbox and single motor entirely and replacing with two U-Drives powered by two separate inverters, each airend stage is now driven directly and independently, for even greater performance. An intelligent digital gearbox design then monitors and adjust the speeds of each aired continuously, ensuring maximum efficiency and pressure ratios at all times.

In addition, the design of the compressor results in hugely reduced friction, resulting in an oil-free compressor with the highest levels of efficiency throughout its full turndown range.

Ulrich Thomes, senior technical engineer from Gardner Denver, who led the engineering team responsible for Ultima’s unique design, commented: “From the outset we had clear requirements for the specification of Ultima’s drive unit and found that no current-generation motor was able to deliver the efficiencies required. U-Drive is a true, next-generation motor and the result of three years’ development. We believe that this is one of the most advanced compressor drive technologies available to customers today and ideal for a pioneering product such as Ultima.”

Historical context

Richard Hilton, product director-industrial compressors at Gardner Denver, explained: “Conventional oil free compressors were first designed in the 1960s and ’70s, and were never designed to be a variable speed machine. The problem with a two-stage oil-free machine is you have two stages – a high-pressure and a low-pressure airend – and the original design concept was that you had one motor with a large full gear and a gearbox, and that drives both the high-pressure and the low-pressure airend.

“However, because there is only one motor and one drive, when the machine is speeded up up and slowed down, whatever rate you spin or slow one airend down by the other has to slow down by the same amount – if you slow the high-pressure down by 10% the low-pressure goes down by 10%. But, every air and has an optimum level where it is at its maximum efficiency. It may be that the high-pressure needs to slow down by 10% but the low-pressure needs to speed up by 5% to achieve maximum efficiency. There has never been a motor available that can spin a standard airend up to 22,000 rpm without the use of a gearbox.

“With this in mind, we have worked for 3 years on a new design concept to offer a completely new product. The 3 key components we worked on were: two airends – high-pressure and the low-pressure – completely built and designed by Gardner Denver; a hybrid motor also of our own design; and a new drive system. The result is a product that is unique in the market.”

Maximum energy recovery

Around 94% of compressor energy is converted in to heat, which, unless it is captured, is vented in to the atmosphere as wasted energy. Ultima uses a bespoke, closed loop water cooling system to ensure that the maximum amount of energy can be recovered from the complete compressor package, taking heat directly from the major components, including the motors, inverters, airend jackets and the oil circuit.

This results in up to 12% better overall heat recovery than a standard two-stage oil-free compressor, for even greater levels of efficiency. Furthermore, Ultima also acts as a high-efficiency water heater, heating the cold water that enters the compressor, which can then be used for other applications.

Superior cooling and ventilation

For maximum efficiency, the air entering a compressor should be as cool and dense as possible, so Ultima is engineered to ensure that no warm air is vented in to the compressor room. Instead, this warm air is processed within the machine enclosure and, using a heat exchanger, the air is cooled and then recirculated via the base frame around the compressor. As a result, no heat is wasted, no dust or particulate matter enters the compressor and the inlet air stays cool.

This also helps to reduce installation time and expense significantly as there is no requirement for additional ducting.

Low noise level

With a noise level of only 69 dB(A), Ultima is extremely quiet, meaning that Ultima can be installed easily at the point of use, rather than housed in a separate compressor room, eliminating the need to install and maintain pipework, to maximise efficiency further.

Energy optimised

Ultima’s engineering team have considered energy consumption at every stage of the design, to create a compressor which, in idle mode, uses 45% less energy than a conventional 2-stage compressor. This can require as little as 8kW of electricity to power a 160kW compressor when idling.

Elsewhere, an intelligent control concept has eliminated the need for an air unloader valve, effectively eliminating the pressure drop that occurs as a result of a compressor controlling the volume of air entering the aired. This also improves maintenance efficiency, as it is one less component to service and replace routinely.

Design excellence

Ultima uses approximately 20% less parts than a standard oil-free compressor, helping to reduce maintenance requirements and compressor reliability.

Upgradable

Hilton explained that Ultima is upgradable. “There are 5 models in the range, from 75 to 160 kW (U75, U90, U110, U132, U160), and any of the lower 4 models can be easily upgraded to any higher output model within an hour; so no lengthy downtime as machines are taken out and replaced. The upgrade is painless – you only need to pay for what your factory actually requires. Ultima can grow as your business grows.”

Frank Klaus, engineering manager GD Simmern, Ultima's project leader, concluded: “Our team has worked so hard to bring this product to market, and I am proud of what we have achieved.”

www.gardnerdenver.com




Events
 
Buyers' Guide Search
 
Search for UK supplier by name
Browse by Product Group.
Magazine
MARCH 2024To view a digital copy of the MARCH 2024 edition of Hydraulics & Pneumatics Magazine, click here.

For a FREE subscription please click here

To visit the Library for past issues click here

JANUARY/FEBRUARY 2024 IssueTo view a digital copy of the JANUARY/FEBRUARY 2024 edition of Hydraulics & Pneumatics Magazine, click here.

For a FREE subscription please click here

To visit the Library for past issues click here

JULY/AUG 2023 Issue inc. BUYERS' GUIDETo view a digital copy of the JULY/AUGUST ISSUE of Hydraulics & Pneumatics magazine that includes the ANNUAL BUYERS' Guide for 2023, click here.

To visit the Library for past issues click here

BFPA YearbookTo read the latest BFPA Yearbook, click here ..
BFPA Training AcademyClick the image to go to the BFPA Training Academy website
Compressed Air & Vacuum Technology Guide 2018To read the official BCAS Compressed Air & Vacuum Technology Guide 2018 click here
Offshore Europe Journal
Newsletter
 
Newsletter